P0130

CIRCUIT DESCRIPTION
Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started the powertrain control module (PCM) operates in an Open Loop mode, ignoring the HO2S signal voltage when calculating the air-to-fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of about 450 mV. The HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage once in Closed Loop. A high HO2S voltage output indicates a rich fuel mixture. A low HO2S voltage output indicates a lean mixture. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature, and to provide an accurate voltage signal. This DTC will set if the PCM receives an active HO2S 1 signal of a lower than calibrated minimum amplitude.

Each HO2S 1 has the following circuits:
^ HO2S 1 high signal
^ HO2S 1 low reference
^ HO2S 1 heater ignition voltage
^ HO2S 1 heater low control Low reference loop

CONDITIONS FOR RUNNING THE DTC
^ DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0410, P0440, P0442, P0443, P0446, P0449, or P1441 are not set.
^ The engine has been running for at least 4 minutes.
^ The mass air flow (MAF) is between 8-35 g/s.
^ The engine speed is between 550-3,000 RPM.
^ The throttle angle is between 3-35 percent.
^ The system voltage is between 9-18 volts.
^ The engine coolant temperature (ECT) is more than 70°C (158°F).

CONDITIONS FOR SETTING THE DTC
The PCM detects an active sensor with an improper voltage signal amplitude.

ACTION TAKEN WHEN THE DTC SETS
The PCM illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.

The PCM records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the PCM stores this information in the failure records. If the diagnostic reports a failure on the second consecutive ignition cycle, the PCM records the operating conditions at the time of the failure. The PCM writes the operating conditions to the Freeze Frame and updates the Failure Records.

CONDITIONS FOR CLEARING THE MIL/DTC
^ The PCM turns off the MIL lamp after 3 consecutive ignition cycles that the diagnostic runs and passes.
^ A current, DTC last test fails, clears when the diagnostic runs and passes.
^ A DTC stored in history clears after 40 warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
^ A scan tool can be used to clear the DTC.

TEST DESCRIPTION

Steps 1-7:




Steps 8-15:




The numbers below refer to the step numbers on the diagnostic table.
2. The HO2S 1 voltage may default to the Bias voltage. The DTC should be cleared and the Freeze Frame/Failure Records data recorded before proceeding. A normally functioning HO2S 1 voltage signal will fluctuate above and below the bias voltage amount.
4. A voltage reading other than the specified amount in this step indicates an open circuit condition in the high signal circuit or the PCM.
6. This step inspects the HO2S 1 signal circuits from the HO2S connector and the PCM connectors, including the low reference loop between the PCM connectors.
8. This step inspects for correct HO2S 1 heater circuit operation up to the HO2S connector. The heater low control is controlled by the PCM. The engine must be running to enable the HO2S heater.
9. The conditions listed in the table may contribute to the failure of the HO2S. The conditions listed apply only to this type of failure.