Manifold Pressure/Vacuum Sensor: Service and Repair
MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Remove the manifold absolute pressure (MAP) sensor screws.
2. Disconnect the MAP sensor electrical connector.
3. Remove the inlet vacuum hose from the map sensor.
4. Remove the MAP sensor from the bracket.
INSTALLATION PROCEDURE
1. Position the MAP sensor to the bracket.
2. Install the inlet vacuum hose to the MAP sensor.
3. Connect the MAP sensor electrical connector.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the MAP sensor screws.
Tighten
Tighten the screws to 3 N.m (27 lb in).