Operation CHARM: Car repair manuals for everyone.

Interior - Door Panel Backlighting Remains On

File In Section: 08 - Body and Accessories

Bulletin No.: 01-08-47-002

Date: November, 2001

TECHNICAL

Subject:
Backlighting on Driver and Passenger Door Switches Remains On, High Parasitic Current Draw Occurs (Replace HTR & A/C Programmer Asm [Instrument Panel Module])

Models:
2000-2002 Buick LeSabre Limited
(Built Prior to VIN Breakpoint 2U132314 - Hamtramck Plant)
2001-2002 Oldsmobile Aurora (Built Prior to VIN Breakpoint 24130554)
2000-2002 Pontiac Bonneville (Built Prior to VIN Breakpoint 24130554)
With RPO CJ2

Condition

Some customers may comment on the following:

^ The vehicle is parked and locked and sits for a minimum of 3.5 minutes. Current draw on the battery is approximately 20 milliamperes.

^ The Remote Keyless Entry (RKE) trunk unlock button is depressed and the trunk is opened and closed again within 10 seconds.

^ The door panel backlighting for the power door locks, power windows, 0/S mirror control, passenger temperature control, memory and heated seat switches remains on. Current draw on the battery is now approximately 720 milliamperes.

^ The backlighting remains on until the RKE door lock or unlock button is activated.

Cause

This high parasitic current draw on the battery may be due to a unique software issue within the Instrument Panel Module (1PM), also referred to as the HTR & A/C Programmer Assembly.

Correction

Modifications have been made to the 1PM software.

1. Replace the 1PM, described as the HTR & NC Programmer Assembly in Parts Information. Refer to the Body Control System sub-section in the Service Manual for replacement procedures. Refer to the following chart for replacement procedures within SI2000.





2. Reprogram the 1PM, described as the HTR & A/C Programmer Assembly in Parts Information. Refer to the chart for reprogramming procedures within SI2000.





Parts Information

Parts are currently available from GMSPO.

Warranty Information





For vehicles repaired under warranty, use the table.





Disclaimer