Control Module HVAC: Service and Repair
REMOVAL PROCEDURE1. Remove the right side IP insulator Panel.
2. Disconnect the electrical connector from the blower motor control processor.
3. Disconnect the blower motor control processor electrical connector from the blower motor.
4. Loosen both of the forward bolts.
IMPORTANT: The opening to the blower motor control processor is slotted. Access to the blower motor control processor opening is limited.
5. Remove the rearward bolt.
6. Remove the blower control processor.
IMPORTANT: Tilt down the rear of the blower motor control processor.
INSTALLATION PROCEDURE
1. Install the blower motor control processor.
IMPORTANT: Align the blower motor control processor forward retaining slots onto the screws and seat the blower motor control processor against HVAC module.
2. Install the blower motor control processor rearward screw.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screw to 1.5 N.m (13 lb in).
3. Tighten the blower motor control processor forward screws.
Tighten
Tighten the screws to 1.5 N.m (13 lb in).
4. Connect the blower motor control processor electrical connector to the blower motor.
5. Connect the electrical connector from the blower motor control processor.
6. Install the right side IP insulator.