Air Conditioning (A/C) Refrigerant Pressure Sensor
TOOLS REQUIREDJ 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the air cleaner assembly.
2. Disconnect the A/C refrigerant pressure sensor from the electrical connector.
3. Remove the A/C refrigerant pressure sensor from the condenser tube.
INSTALLATION PROCEDURE
1. Install the new O-ring seal.
2. Install the A/C refrigerant pressure sensor to the condenser tube.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the sensor to 4.7 N.m (41 lb in).
3. Connect the A/C refrigerant pressure sensor to the electrical connector.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.