Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the air cleaner assembly.
2. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
3. Remove the refrigerant pressure sensor from the liquid line.
INSTALLATION PROCEDURE
1. Install the new O-ring seal.
2. Install the refrigerant pressure sensor to the liquid line.
Tighten the sensor to 4.7 N.m (41 lb in).
NOTE: Refer to Fastener Notice.
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.