Blower Motor: Service and Repair
Blower Motor Replacement
Removal Procedure
1. Remove the right side instrument panel insulator.
2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor.
Installation Procedure
1. Install the blower motor.
Notice: Refer to Fastener Notice.
2. Install the blower motor screws.
Tighten the screws to 1.5 N.m (13 lb in).
3. Connect the blower motor electrical connector.
4. Install the right side instrument panel insulator.