Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake
CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT SIDE) INTAKE
REMOVAL PROCEDURE
1. Turn the ignition OFF.
2. Remove the ECM bracket bolts and reposition the ECM bracket in order to provide access.
IMPORTANT: Do not remove the engine control module (ECM) from the ECM bracket.
Do not remove the ECM redundant ground wire from the ECM.
3. Remove the camshaft position (CMP) actuator valve electrical connector.
4. Remove the CMP actuator valve bolt.
5. Remove the CMP actuator valve.
INSTALLATION PROCEDURE
1. Install the CMP actuator valve.
2. Install the CMP actuator valve bolt.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the CMP actuator valve bolt to 10 Nm (89 lb in).
3. Install the CMP actuator valve electrical connector.
4. Install the ECM bracket with the ECM.