Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
1. Remove the air cleaner assembly.
2. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
3. Remove the refrigerant pressure sensor from the liquid line.
Installation Procedure
1. Install the new O-ring seal.
Notice: Refer to Fastener Notice.
2. Install the refrigerant pressure sensor to the liquid line.
Tighten the sensor to 4.7 N.m (41 lb in).
3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Install the air cleaner assembly.
5. Leak test the fittings of the component using J 39400-A.