OSS Sensor and Cooler Fitting Installation
OSS Sensor and Cooler Fitting Installation
1. Inspect the output speed sensor (130) for damage or a cut seal (4).
2. Inspect the cooler connector (3) for damaged threads, clogging, or a cut seal (4).
3. Install the output speed sensor (130) and the seal (4).
Notice: Refer to Fastener Notice in Service Precautions.
4. Install the output speed sensor bolt (131).
Tighten the bolt to 8-14 N.m (6-10 lb ft).
5. Install the cooler fitting (3) and the new seal (4) or fitting (38) and seal (39) into the case.
Tighten the cooler fitting to 25-29 N.m (19-21 lb ft).