Blower Motor: Service and Repair
Blower Motor Replacement
Removal Procedure
1. Remove the right side instrument panel insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side (Service and Repair).
2. Disconnect the blower motor electrical connector.
3. Remove the blower motor mounting screws.
4. Remove the blower motor.
Installation Procedure
1. Install the blower motor.
Notice: Refer to Fastener Notice (Fastener Notice).
2. Install the blower motor screws.
Tighten the screws to 1.5 N.m (13 lb in).
3. Connect the blower motor electrical connector.
4. Install the right side instrument panel insulator. Refer to Instrument Panel Insulator Panel Replacement - Right Side (Service and Repair).