Transmission Pressure Test Port: Service and Repair
Automatic Transmission Fluid Pressure Test Hole Plug Replacement
Removal Procedure
1. Remove the air cleaner intake duct. Refer to Air Cleaner Inlet Duct Replacement ().
2. Remove the line pressure pipe plug (38).
Installation Procedure
1. Apply GM P/N 12345382 (Canadian P/N 10953489) or equivalent to the line pressure pipe plug.
Notice: Refer to Fastener Notice.
2. Install the line pressure pipe plug (38).
Tighten the plug to 11 N.m (97 lb in).
3. Install the air cleaner intake duct. Refer to Air Cleaner Inlet Duct Replacement ().