Manual Valve Link and Fluid Dam Assemble
Manual Valve Link and Fluid Dam Assemble
1. Install the oil dam (27) into the case.
2. Assemble the manual valve link onto the manual shift detent lever/IMS detent lever.
3. Connect the manual valve link (402) to the manual valve (404).
4. Install the manual valve link spring (403).
Caution: Refer to Fastener Caution (Fastener Caution).
5. Install the manual shift detent assembly (804), and the manual shift detent bolt (805) and tighten to 12 Nm (106 lb in).
6. Carefully install the input speed sensor (440) into the case cover (400).
7. Install the input speed sensor clip (441) into the case cover (400).