Fuel Level Sensor: Service and Repair
Fuel Level Sensor Replacement
Removal Procedure
Warning
Fuel Vapors can collect while servicing fuel system parts in enclosed areas such as a trunk. To reduce the risk of fire and increased exposure to vapors:
* Use forced air ventilation such as a fan set outside of the trunk.
* Plug or cap any fuel system openings in order to reduce fuel vapor formation.
* Clean up any spilled fuel immediately.
* Avoid sparks and any source of ignition.
* Use signs to alert others in the work area that fuel system work is in process.
1. Remove the fuel tank pump module. Refer to Fuel Tank Fuel Pump Module Replacement (NT7) (Fuel Tank Fuel Pump Module Replacement (NT7))Fuel Tank Fuel Pump Module Replacement (NU6) (Fuel Tank Fuel Pump Module Replacement (NU6)).
2. Using two flat-bladed tools, carefully pull both locking tabs (1) outward while simultaneously lifting the level sensor.
3. Using a small bladed tool, gently release the retaining tabs on the electrical terminals (1) while simultaneously pulling the terminals out.
4. Inspect the terminals for bending and reposition as necessary.
Installation Procedure
1. Push in the electrical terminals (1) and ensure the terminals are secure.
2. Carefully insert the level sensor until the locking tabs (1) snap into the locking position.
3. Install the fuel tank pump module. Refer to Fuel Tank Fuel Pump Module Replacement (NT7) (Fuel Tank Fuel Pump Module Replacement (NT7))Fuel Tank Fuel Pump Module Replacement (NU6) (Fuel Tank Fuel Pump Module Replacement (NU6)).