Operation CHARM: Car repair manuals for everyone.

P1E0A




DTC P1E0A

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P1E0A

-
Drive Motor Control Module Torque Calculation Performance

Circuit/System Description

The generator control module also called the starter generator control module is comprised of the following three control modules; the hybrid powertrain control module, 14 volt power module and the drive motor control module. These three control modules are non serviceable and are part of the generator control module.

This is an internal fault detection of generator control module and no external circuits are involved.

Conditions for Running the DTC

The ignition voltage is greater than 9.5 V.

Conditions for Setting the DTC

The difference between the redundant torque calculation and the primary calculation is greater than 36 Nm(27 lb ft).

Action Taken When the DTC Sets

* DTC P1E0A is a Type A DTC.

* The hybrid powertrain control module opens the high voltage contactor relay.

Conditions for Clearing the DTC

DTC P1E0A is a Type A DTC.

Reference Information

Description and Operation

* Starter Generator Description and Operation Starter Generator Description and Operation

* Generator Control Module Description and Operation Generator Control Module Description and Operation

* Hybrid Modes of Operation Description Hybrid Modes of Operation Description

DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Circuit/System Verification

Program the K59 starter generator control module. If the DTC resets replace the K59 starter generator control module.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the repair.

Control Module References Programming and Relearning for Generator Control Module, also called the Starter Generator Control Module, replacement, programming and setup.