Drive Motor Battery Wire Junction Block Relay Replacement




Drive Motor Battery Wire Junction Block Relay Replacement

Removal Procedure

Danger:
Ensure all High Voltage safety procedures are followed. Failure to follow the procedure exactly as written may result in serious injury or death.


Danger:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.


The High Voltage Disabling procedure will perform the following tasks:


* Identify how to disable high voltage.


* Identify how to test for the presence of high voltage.


* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.


Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:


* Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.


* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.


- Visually and functionally inspect the gloves before use.


- Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.


Failure to follow the procedures exactly as written may result in serious injury or death.


1. Ignition OFF, disable the high voltage at the A4 hybrid battery pack. Refer to High Voltage Disabling High Voltage Disabling.





2. Remove the high voltage fasteners (1) and the high voltage cables (2) from the drive motor battery junction block relay.





3. Remove the cut-off switch fastener (1) and set aside the cut-off switch (2).





4. Remove the generator battery disconnect relay fasteners (1) and remove the drive motor battery junction block relay (2).

Installation Procedure





Caution:
Refer to Fastener Caution Fastener Caution.

1. Install the drive motor battery junction block relay (2) to the generator control module and tighten the fasteners (1) to 9 Nm (80 lb in).





2. Install the cut-off switch (2) to the drive motor battery junction block relay and tighten the fastener (1) to 4 Nm (35 lb in).





3. Install the high voltage cables (2) to the drive motor battery junction block relay and tighten the fasteners (1) to 9 Nm (80 lb in).

4. Enable the hybrid battery. Refer to High Voltage Enabling High Voltage Enabling.