Operation CHARM: Car repair manuals for everyone.

Generator Battery Control Wiring Harness Replacement (B2 to BDU1 Contactor)




Generator Battery Control Wiring Harness Replacement (B2 to BDU1 Contactor)

Removal Procedure

Danger:
Ensure all High Voltage safety procedures are followed. Failure to follow the procedure exactly as written may result in serious injury or death.


Danger:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.


The High Voltage Disabling procedure will perform the following tasks:


* Identify how to disable high voltage.


* Identify how to test for the presence of high voltage.


* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.


Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:


* Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.


* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.


- Visually and functionally inspect the gloves before use.


- Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.


Failure to follow the procedures exactly as written may result in serious injury or death.


1. Disable the hybrid battery. Refer to High Voltage Disabling High Voltage Disabling.





2. Remove the high voltage cable fastener (1) and the high voltage cable (2), from the generator battery disconnect relay junction block (3).

Installation Procedure





Caution:
Refer to Fastener Caution Fastener Caution.

1. Install the the high voltage cable (2), to the generator battery disconnect relay junction block (3) and tighten the fastener (1) to 9 Nm (80 lb in).

2. Enable the hybrid battery. Refer to High Voltage Enabling High Voltage Enabling.