Generator Control Module Replacement
Generator Control Module Replacement
Removal Procedure
Danger:
Ensure all High Voltage safety procedures are followed. Failure to follow the procedure exactly as written may result in serious injury or death.
Danger:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
* Identify how to disable high voltage.
* Identify how to test for the presence of high voltage.
* Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.
Before working on any high voltage system, be sure to wear the following Personal Protection Equipment:
* Safety glasses with appropriate side shields when within 15 meters (50 feet) of the vehicle, either indoors or outdoors.
* Certified and up-to-date Class "0" Insulation gloves rated at 1000V with leather protectors.
- Visually and functionally inspect the gloves before use.
- Wear the Insulation gloves with leather protectors at all times when working with the high voltage battery assembly, whether the system is energized or not.
Failure to follow the procedures exactly as written may result in serious injury or death.
1. Ignition OFF, disable the high voltage at the A4 hybrid battery pack. Refer to High Voltage Disabling, for Servicing Internal Components within the A4 Hybrid/EV Battery Pack High Voltage Disabling High Voltage Disabling.
2. Disconnect the generator control module connector (1).
3. Remove the fasteners (1) securing the drive motor battery wire junction block relay (2), to the top of the generator control module.
4. Remove the fasteners (3) securing the battery energy control module wiring junction block (4), to the top of the generator control module.
5. Remove the high voltage bus fasteners (1) from the battery energy control module wiring junction block (2).
6. Lift the drive motor battery wire junction block relay (1) and the battery energy control module wiring junction block with the harness attached, and place on top of the battery energy control module (3).
7. Remove the generator control module mounting fasteners (1) and (2).
8. Remove the generator control module (3) from the support tray.
Installation Procedure
1. Inspect the foam seals for tears and leak paths, to ensure they will not compromise the internal air flow through the generator control module assembly.
Caution:
Refer to Fastener Caution Fastener Caution.
2. Install the generator control module (3) to the support tray studs. Tighten the fastener (1) to 9 Nm (80 lb in).
Note:
Do not slide the generator control module on the foam seals as the seals may become damaged.
3. Tighten the remaining fasteners (2) to 9 Nm (80 lb in).
4. Place the drive motor battery wire junction block relay (1) and the battery energy control module wiring junction block (2), on top of the generator control module.
5. Install the high voltage bus fasteners (1) to the battery energy control module wiring junction block (2) and tighten to 9 Nm (80 lb in).
6. Install the battery energy control module wiring junction block fasteners (1) and tighten to 9 Nm (80 lb in).
7. Install the battery energy control module wiring junction block fasteners (2) and tighten to 9 Nm (80 lb in).
8. Connect the generator control module connector (1).
9. Enable the high voltage at the A4 hybrid battery pack. Refer to High Voltage Enabling High Voltage Enabling.
10. Program the generator control module. Refer to Control Module References Programming and Relearning.