Operation CHARM: Car repair manuals for everyone.

Blower Motor: Service and Repair




Blower Motor Replacement

Removal Procedure

1. Remove the instrument panel lower extension compartment panel. Refer to Instrument Panel Lower Extension Compartment Panel Replacement Instrument Panel Lower Extension Compartment Panel Replacement.

2. Remove the front floor air outlet duct - right side. Refer to Floor Front Air Outlet Duct Replacement - Right Side Floor Front Air Outlet Duct Replacement - Right Side.

3. Disconnect the blower motor electrical connector.




4. Remove the 3 blower motor cup bolts (1).

5. Remove the blower motor cup from the blower motor (2).




6. Remove the blower motor bolts (1).

7. Remove the blower motor (2) from the heater case.

Installation Procedure




1. Install the new blower motor (2) to the heater case.

Caution: Refer to Fastener Caution Fastener Caution.

2. Install the 3 blower motor bolts (1) and tighten to 4.5 Nm (40 lb in).

3. Install the motor blower cup to the blower motor.

4. Install the blower motor cup bolts and tighten to 2.5 Nm (22 lb in).

5. Connect the blower motor electrical connector.

6. Install the front floor air outlet duct- right side. Refer to Floor Front Air Outlet Duct Replacement - Right Side Floor Front Air Outlet Duct Replacement - Right Side.

7. Install the instrument panel lower extension compartment panel. Refer to Instrument Panel Lower Extension Compartment Panel Replacement Instrument Panel Lower Extension Compartment Panel Replacement.