Accumulator HVAC: Service and Repair
ACCUMULATOR REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Disconnect the electrical connector from the A/C low pressure switch.
3. Remove the compressor hose nut from the accumulator.
4. Disconnect the compressor hose from the accumulator.
5. Remove the nut (2) from the evaporator fitting.
6. Remove the accumulator bracket nut (4) from the retaining stud.
7. Remove the accumulator (3).
8. Remove the retaining bracket bolt (5).
9. Remove the retaining bracket (6) from the accumulator.
10. Remove the O-ring seals.
INSTALLATION PROCEDURE
1. Install new O-ring seals.
2. Install the retaining bracket (6) to the accumulator.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the retaining bracket bolt (5).
Tighten
Tighten the accumulator bracket bolt to 10 N.m (89 lb in).
4. Install the accumulator (3).
5. Install the accumulator bracket nut (4).
Tighten
Tighten the accumulator bracket nut to 9 N.m (80 lb in).
6. Install the nut (2) to the evaporator fitting.
Tighten
Tighten the nut to 16 N.m (12 lb ft).
7. Connect the compressor hose to the accumulator.
8. Install the compressor hose nut to the accumulator.
Tighten
Tighten the compressor hose nut to 16 N.m (12 lb ft).
9. Connect the electrical connector to the A/C low pressure switch.
10. Evacuate and recharge the system. Refer to Refrigerant Recovery and Recharging.
11. Leak test the fittings of the component using the J 39400-A.