Recirculation Mode
The recirculation door will move automatically with an input from the A/C high pressure recirculation switch at approximately
2413 kPa (350 psi). The PCM will place the A/C system in recirculation mode when a signal is sent over the A/C
refrigerant high pressure cut-out switch signal circuit. The
recirculation actuator door control circuit is grounded by the PCM to ensure that the actuator is forced to the recirculation position. This allows for the cooler inside air to flow over the A/C evaporator and cool the refrigerant, until the high side pressure returns to normal. This action will allow the high side pressure to return to normal pressure at a faster pace. The recirculation door will move back to the outside air position when the high side pressure reaches
1724 kPa (250 psi).