B0179
CIRCUIT DESCRIPTIONThe HVAC control module monitors the air temperature in the floor discharge duct via a lower air temperature sensor. When the air is cold, the sensor resistance and the signal voltage are high. When the air is warm, the sensor resistance and the signal voltage are low.
CONDITIONS FOR RUNNING THE DTC
The ignition is turned ON.
CONDITIONS FOR SETTING THE DTC
The HVAC control module detects the signal circuit is less than 5 Counts (0.09 V) or greater than 250 Counts (4.90 V).
ACTION TAKEN WHEN THE DTC SETS
A default value will be used for the sensor data by the HVAC control module. The actual value of the sensor will be displayed on the scan tool.
CONDITIONS FOR CLEARING THE DTC
- The DTC will become history if the HVAC control module no longer detects a condition.
- The history DTC clears after 50 fault free ignition cycles.
- The DTC can be cleared with a scan tool.
DIAGNOSTIC AIDS
If the condition is not present, refer to Testing for Intermittent and Poor Connections in Diagnostic Aids.
TEST DESCRIPTION
Steps 1-4:
Steps 5-12:
The number(s) below refer to the step number(s) on the diagnostic table.
3. Tests for the proper operation of the circuit in the high voltage range.
4. Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.