W/Case Grounded HO2S
CIRCUIT DESCRIPTIONThis diagnostic applies only to vehicles built with case grounded heated oxygen sensors (HO2S). To identify the HO2S, refer to Computers and Controls Systems Component Views.
The powertrain control module (PCM) supplies a voltage of about 450 mV between the HO2S high and low signal circuits. The oxygen sensor varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.
The PCM monitors and stores the HO2S voltage information. The PCM evaluates the HO2S voltage samples in order to determine the amount of time the HO2S voltage was out of range. The PCM compares the stored HO2S voltage samples taken within each sample period and determines if the majority of the samples are out of the operating range.
The PCM monitors the HO2S voltage and detects if the voltage goes out of the bias range. If the PCM does not detect the voltage went out of the bias range, a diagnostic trouble code (DTC) sets.
CONDITIONS FOR RUNNING THE DTC
^ DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0200, P0300, P0401, P0404, P0405, P0440, P0442, P0446, P0452, P0453, P1120, P1125, P1220, P1221, P1258, P1404, P1441, P1514, P1515, P1516, P1517, or P1518 are not set.
^ The engine run time is more than 409 seconds.
^ The vehicle is operating in Closed Loop.
^ The ignition 1 signal is between 9-18 volts.
^ Intrusive tests are not in progress.
^ The scan tool output controls are not active.
CONDITIONS FOR SETTING THE DTC
^ The HO2S voltage is steady between 410-490 mV for 150 seconds.
^ The TP changes more than 5 percent within 1 second, 6 times.
ACTION TAKEN WHEN THE DTC SETS
^ The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
^ The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
^ The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
^ A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
^ A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
^ Clear the MIL and the DTC with a scan tool.
DIAGNOSTIC AIDS
IMPORTANT: Remove any debris from the PCM connector surfaces before servicing the PCM. Inspect the PCM connector gaskets when diagnosing or replacing the PCM. Ensure that the gaskets are installed correctly. The gaskets prevent water intrusion into the PCM.
^ An oxygen supply inside the HO2S is necessary for proper operation. The HO2S wires provides the supply of oxygen. Inspect the HO2S wires and connections for breaks or contamination. Refer to Heated Oxygen Sensor (HO2S) Wiring Repairs in Diagnostic Aids.
^ For an intermittent condition, refer to Intermittent Conditions.
TEST DESCRIPTION
Steps 1-7:
Steps 8-16:
Steps 17-22:
The numbers below refer to the step numbers on the diagnostic table.
2. After the ignition is turned ON, the HO2S heater heats up causing the HO2S signal voltage to either increase or decrease. This indicates that the HO2S heater is OK.
3. If the HO2S voltage is varying outside the specified range, the condition is not present.
5. If the voltage is below the specified value, the high signal circuit, the low signal circuit, and the PCM are OK.
6. If the voltage is above the specified value, the low signal circuit is OK.
12. The opposite bank HO2S must be disconnected to isolate a short to ground in the HO2S heater ignition 1 voltage circuit.
14. Resistance within the specified range indicates the HO2S heater is OK.