Blower Motor Replacement (Right Hand Drive)



Blower Motor Replacement (Right Hand Drive)

Removal Procedure

1. Remove the left closeout insulator panel.
2. Remove the instrument panel (I/P) compartment.




3. Disconnect the blower motor electrical connector.




4. Disconnect the blower motor processor electrical connector.




5. Remove the screws (1) that retain the blower motor.




6. Remove the blower motor.

Installation Procedure




1. Install the blower motor.






Notice: Refer to Fastener Notice.

2. Install the blower motor screws (1).

Tighten the screws to 1.5 N.m (13 lb in).




3. Connect the blower motor processor electrical connector.




4. Connect the blower motor electrical connector.
5. Install the I/P compartment.
6. Install the left insulator panel.