Air Cleaner Housing: Service and Repair
Air Cleaner Assembly Replacement
Removal Procedure
1. Turn the ignition OFF.
2. Remove the air cleaner intake duct. Refer to Air Cleaner Inlet Duct Replacement (Service and Repair) .
3. Disconnect the mass air flow (MAF) electrical connector.
4. Remove the air cleaner bolts.
5. Remove the air cleaner.
Installation Procedure
1. Install the air cleaner.
Notice: Refer to Fastener Notice (Fastener Notice) .
2. Install the air cleaner bolts.
Tighten the air cleaner bolts to 9 N.m (78 lb in).
3. Connect the MAF electrical connector.
4. Install the air cleaner intake duct. Refer to Air Cleaner Inlet Duct Replacement (Service and Repair) .