Operation CHARM: Car repair manuals for everyone.

A/C - No Low Blower Operation

87cad6

Bulletin No. T 88-14
File in Group 1
Number 40
Corp. Ref. No. 711209
Date Sept. '87
SUBJECT: NO LOW BLOWER OPERATION

MODELS AFFECTED: 1981-1987 REAR-WHEEL-DRIVE DE VILLE AND BROUGHAM 1980-1985 ELDORADO AND SEVILLE

Some 1981-1987 RWD De Villes and Broughams, and 1980-1985 Eldorados and Sevilles equipped with a non-BCM controlled ECC system may experience a condition of no low blower operation. This condition may be caused by a crossfeed on circuit 976. Confirm a no low blower condition by selecting the low setting on the ECC head and checking the voltage across the blower motor terminals. If this voltage is above 6 volts, the ECC system is not achieving low blower operation. Repair this condition using the following procedure:

1. Cut circuit 976 on both sides of the center bulkhead connector (C101).

2. Run a jumper wire through an open connector cavity.

3. Splice the harness wiring to this jumper on both sides of the bulkhead connector.
For warranty purposes, use Labor Operation N6030 at .5 hour.