Suspension Control - Computer Command Ride (CCR/SSS)
TEST CONDITIONS:
The Control Module will monitor the mercury switch accelerometer signal for invalid voltage levels.
FAULT CONDITIONS:
If accelerometer voltage is too high or too low, set code.
ACTION TAKEN:
Record mercury switch accelerometer error,
Turn on "SERVICE CCR" telltale lamp,
Disable accelerometer switch input until valid voltage level is detected.
DESCRIPTION:
A mercury switch accelerometer error occurs when the accelerometer signal is short circuited to B+ or ground, or the accelerometer is open-circuited or disconnected Recovery occurs upon detection of valid accelerometer input voltage.