Front Blower Motor Replacement
1. Disconnect battery ground cable, then remove strut tower cross brace (two nuts each side).
2. Remove cowl relay center bracket (two nuts), then disconnect electrical connector and cooling hose from blower motor.
3. On Eldorado and Seville models, Remove MAP sensor mounting bracket.
4. On all models, remove blower motor retaining screws, then tilt blower motor in case to allow fan removal. Fan must be removed prior to blower motor to prevent fan from being bent.
5. Remove fan retainer and fan from blower motor, then remove blower motor.
6. Remove blower fan from case.