DTC 32
Electrical Diagram:
CIRCUIT DESCRIPTION
The voltage at the "Sense Low" input, terminal A6," is between 41% and 61% of "36VLR" output voltage when "36vLR" output of the DERM is charged. Should the circuit short to ground between the "36VLR" output and Diode "B," "Ignition 1" voltage will be supplying the deployment loop. The voltage at the "Sense Low" input terminal "A6" will decrease due to the lower supply voltage and Code 32 will set after 700 milliseconds. Code 32 indicates a short to ground in the wiring between the "36VLR" output of the DERM and the arming sensor.
TEST CONDITION(S)
Test every 100 milliseconds during "Continuous Monitoring".
FAILURE CONDITION(S)
Code 32 wilt set if the voltage at the "Sense Low" input, terminal "A6," is between 28% and 59% of "Ignition 1" voltage for 700 milliseconds and Code 42 is set.
ACTION TAKEN
DERM turns ON the "INFL REST" warning lamp.
CONDITIONS TO CLEAR
Current Code 32 will clear if the voltage at the "Sense Low" input, terminal A6," is between 41% and 61% of "36VLR" output voltage for 500 milliseconds.
TEST DESCRIPTION
Number(s) below refer to circled number(s) on the diagnostic chart.
1. This test checks for a short from the "36VLR" circuit to ground.
2. This test determines if the short to ground is on CKT 236 wiring or if it is on the arming sensor.