Voltage is applied at all times through Circuit Breaker 24 to the seat recliner switches.
With the switch in the FWD position, voltage is applied through the FWD contact to the seat recliner motor. The motor is grounded through the recline contact to ground G200 (LH) or G201 (RH). The motor runs and the seat back moves forward.
With the switch in the RECLINE position, voltage is applied to the seat recliner motor through the FWD contact to ground G200 (LH) or G201 (RH). The motor runs in the opposite direction and the seat back reclines.