RAP Feature Won't Deactivate When Opening Doors
Test A: Doors Mini Wedge Input Test-Table 1 & 2:
PROCEDURE
Perform mini-wedge test found in the image.
NOTE: To perform the Mini Wedge Input Test, it will be necessary to install a Tech 1 at the DLC using mass storage cartridge #3000003.
If upon using the Tech 1, the Door Mini Wedge Input Display stays at the same state, with no change displayed when shutting or opening the door(s), this condition will have to be repaired first before testing the Door Mini Wedge inputs.
"OPEN" = Door is open, thus Mini Wedge Switch is grounded.
"CLOSE" = Door is shut, thus Mini Wedge Switch is open.
Remove relay(s) and check for stuck contacts. Replace defective relay(s). Check for short to B+ in CKTs 70 & 75. If OK, replace CCM.