Variable Induction Control Valve: Service and Repair
Removal ProcedureCaution: Refer to Gasoline/Gasoline Vapors under Powertrain Management / Service Precautions.
1. Disconnect the negative battery cable.
2. Remove the intake plenum. Refer to Intake Air Plenum.
3. Disconnect the vacuum hose at the actuator.
4. Remove the two switchover valve to plenum bolts.
5. Remove the switchover valve from the intake plenum.
Installation Procedure
1. Install the switchover valve to the intake plenum.
2. Install/tighten the two switchover valve to plenum bolts.
3. Reconnect the vacuum hose at the actuator.
4. Install the intake plenum.
5. Reconnect the negative battery cable.