Oxygen Sensor: Testing and Inspection
Oxygen Sensor DiagnosisDiagnose the Fuel Control Heated Oxygen Sensors (Bank 1 HO2S 1 and Bank 2 HO2S 1) for the following conditions:
^ Heater Performance (time to activity on cold start)
^ Slow Response
^ Response Time (time to switch R/L or L/R)
^ Inactive Signal (output steady at bias voltage approximately 450 mV)
^ Signal Fixed High
^ Signal Fixed Low
Diagnose the Catalyst Monitor Heated Oxygen Sensors (Bank 1 HO2S 2 and Bank 1 HO2S 3) for the following functions:
^ Heater Performance (time to activity on cold start)
^ Slow Response
^ Response Time (time to switch R/L or L/R)
^ Signal fixed low during steady state conditions or power enrichment (hard acceleration when a rich mixture should be indicated)
^ Signal fixed high during steady state conditions or decel fuel mode (deceleration when a lean mixture should be indicated)
^ Inactive Sensor (output steady at approximately 438 mV)