Charging Procedure
NOTE: Always turn the ignition "OFF" when connecting or disconnecting battery cables, battery chargers or jumper cables. Failure to do so may damage the Power Control Module (PCM) or other electrical components.1. Batteries with a "green dot" hydrometer do not require charging unless they have just been discharged (such as in cranking vehicle).
2. When charging side-terminal batteries while on-vehicle, turn off charger and connect positive lead to the positive booster cable terminal located in the engine compartment on the right side. Connect negative charger lead to a solid engine ground, such as the generator mounting bracket.
Battery Side Terminal Adapters:
3. When charging side-terminal batteries out of vehicle, install adapter kit refer to the above image.
Tighten
^ Adapters to 15 N.m (11 lb. ft.).
4. Make sure charger connections are clean and tight.
5. For best results, batteries should be charged when the electrolyte and plates are at room temperature. A battery that is extremely cold may not accept current for several hours after starting charger.
6. Charge battery until green dot appears, refer to Charging Time Required. Battery should be checked every half hour while charging. Tap hydrometer lightly on top to dislodge any trapped air bubbles that may keep the green dot from appearing.
7. After charging, battery should be load tested as outlined in Diagnosis.