A/C Load Signal
The Air Conditioning
(A/C) Load circuit signals the ECM when the A/C compressor system is under an excessive load during, for example, any high ambient conditions. If the system pressure exceeds 1,200 kPa, the ECM will detect this condition and increase the
idle speed by about 50 RPM in order to compensate for the excess load.