DTC B1007 EEPROM Write Error
DTC B1007 EEPROM Write ErrorCircuit Description
The Remote Keyless Entry (RKE) module performs internal tests on the EEPROM each time the RKE module performs a write function to a memory address in the EEPROM. The RKE module reads back the data that has been written and compares it to the data. If the data does not match after three consecutive write and verify attempts, the RKE module will indicate a write malfunction is current.
Conditions for Setting the DTC
^ The data read back after a write does not match the data being written three consecutive times.
^ The RKE module detects an internal write malfunction.
^ The condition must occur when data is being written.
Action Taken When the DTC Sets
^ Stores a DTC B1007 in the RKE memory.
^ No driver warning message will be displayed for this DTC.
^ The RKE module will store the value being written in another memory address in the EEPROM.
Conditions for Clearing the DTC
^ This DTC requires a successful write in order to change from current to history.
^ The RKE module no longer detects an internal write malfunction.
^ A history DTC will clear after 50 consecutive ignition cycles if the condition for the malfunction is no longer present.
^ Use the On-Boards clearing DTCs feature.
^ Use a scan tool.
Diagnostic Aids
Since the EEPROM cannot be removed from the RKE module and DTC B1007 is an internal RKE malfunction, the RKE module will need to be replaced. Refer to diagnostic table (see Attachment 4).
Test Description
The numbers below refer to the step numbers on the diagnostic table (see Attachment 4):
1. Perform the Remote Keyless Entry Diagnostic System Check before continuing with the diagnosis of this DTC.
2. Clear all DTCs and remove and restore battery voltage to check that the DTC did not falsely set.
4. Clear all DTCs after the repair procedure is complete.