Installation Procedure
Description:
1. Install the inflatable restraint front end discriminating sensor (3) to the radiator support.
NOTICE: Refer to Fastener Notice.
2. Install the inflatable restraint front end discriminating sensor mounting fasteners (2).
Tighten
Tighten fastener to 11 N.m (98 lb.in).
Description:
3. Connect the inflatable restraint front end discriminating sensor harness connector (4) to the inflatable restraint front end discriminating sensor.
Description:
4. Install the Connector Position Assurance (CPA) (5) to the inflatable restraint front end discriminating sensor harness connector (4).
5. Enable the frontal SIR system. Refer to Enabling the SIR System.