Installation Procedure
Description:
1. Install the floor retractor to the inner rocker panel with a bolt.
Tighten
Tighten the bolt to 35-48 N.m (26-35 lb. ft).
NOTICE: Refer to Fastener Notice in Service Precautions.
2. Install the height adjuster guide loop and bolts.
Tighten
Tighten the bolt to 35-48 N.m (26-35 lb. ft).
3. Install the height adjuster trim cover and bolts.
Tighten
Tighten the bolt to 1.8 N.m (16 lb.in).
Description:
4. Install the Intermediate Guide bracket with three bolts.
Tighten
Tighten the bolt to 5-7 N.m (44-62 lb.in).
5. Install the carpet retainers.
6. Install the center lock pillar trim.