Operation CHARM: Car repair manuals for everyone.

RH Front Power Window Switch

Battery voltage is applied from the WINDOWS circuit breaker through CKT 42 (RED) to the accessory time delay relay. When the ignition is in RUN or Retained Accessory Power (RAP) is active, the accessory time delay relay supplies voltage through CKT 70 (PNK) to the RH front power window switch. When the UP switch is pressed, voltage is applied to one terminal of the power window motor through CKT 666 (DK BLU). Ground is applied to the opposite terminal of the power window motor from the LH front power window switch through the RH front power window switch on CKT 167 (TAN) and CKT 667 (BRN). When the DOWN switch is pressed, voltage is applied to one terminal of the power window motor through CKT 667 (BRN). Ground is applied to the opposite terminal of the power window motor from the LH front power window switch through the RH front power window switch on CKT 166 (LT BLU) and CKT 666 (DK BLU).