Air Door: Service and Repair
Air Mix Actuators:
Remove or Disconnect
1. Instrument panel compartment.
2. Unsnap rod from the plastic retainer on the actuator arm.
3. Two screws from actuator.
4. Electrical connector.
5. Actuator.
6. Check the air mix door for free travel.
Install or Connect
1. Actuator.
2. Electrical connector.
3. Two screws to actuator.
4. Snap rod to plastic retainer on actuator arm.
5. Instrument panel compartment.
Important
^ After the actuator(s) has been replaced, the actuator needs to be recalibrated for proper travel. The ignition must be cycled ON for three minutes to allow the programmer and the actuator(s) to recalibrate for proper travel.