Interior Coupling Box Installation Procedure
1. Clean the interior glass and the coupling box with alcohol.
2. Dry the components thoroughly using a lint tree cloth.
3. Apply new double back tape.
IMPORTANT: The RF connections for the interior coupling box should run parallel to the defogger gridline.
4. Align the interior coupling box with the exterior mount.
5. Press the interior coupling box onto the back window using even firm pressure at all four corners.
For a description of the RPO Code(s) shown in this image/article refer to the RPO Code List found at Vehicle/Application ID RPO Codes