Scan Tool Data Definitions
CRANK REQUEST: The scan tool displays Yes/No. The scan tool displays No until the ignition is placed into the CRANK position, then it reads Yes.GENERATOR L TERMINAL: The scan tool displays OK/No Output. The scan tool displays OK until malfunction is detected on the generator L terminal circuit, then it reads No Output.
GENERATOR PWM: The scan tool displays 0%-100%. The scan tool displays 0%-5% until the engine is running, then the percentage value varies depending on electrical loads.
STARTER RELAY STATUS: The scan tool displays ON/OFF. The scan tool displays Off until the ignition is placed into the CRANK position, then it reads On.