72. OSS Sensor and Cooler Fitting Installation
1. Inspect the output speed sensor (130) for damage or a cut seal (4).
2. Inspect the cooler connector (3) for damaged threads, clogging, or a cut seal (4).
3. Install the output speed sensor (130) and the seal (4) into the case extension.
4. Install the output speed sensor bolt (131).
- Tighten the bolt to 8-14 Nm (6-10 ft. lbs.).
5. Install the cooler fitting (3) and the new seal (4) into the case.
- Tighten the cooler fitting to 25-29 Nm (19-21 ft. lbs.).