Operation CHARM: Car repair manuals for everyone.

Cornering Lamp: Description and Operation

CORNERING LAMPS

When the low beam relay K131 is energized, battery voltage is supplied to fuse #31. Fuse #31 supplies battery voltage to the turn signal switch. When the turn signal switch is engaged to the "TURN RIGHT" position, battery voltage is supplied to the RH cornering lamp through the turn signal switch. When the turn signal switch is engaged to the "TURN LEFT" position, battery voltage is supplied to the LH cornering lamp through the turn signal switch. The LH and RH cornering lamps are permanently grounded to G103.