O-Ring Replacement
O-RING REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
2. Disconnect the A/C refrigerant line.
^ For compression style fittings use a back up wrench on the fitting (2) and loosen the fitting nut (1).
^ For banjo style fittings remove the bolt retaining the banjo type fitting.
IMPORTANT: Cap or tape the open A/C refrigerant line and the A/C refrigerant component immediately.
3. Disconnect the A/C line from the A/C component.
4. Cap or tape the A/C line and the A/C component to prevent system contamination, discard the O-ring seals.
INSTALLATION PROCEDURE
1. Remove the cap or tape from the A/C line and the A/C component.
2. Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the A/C refrigerant line and the A/C refrigerant component.
3. Lightly coat the new O-ring seal with mineral base 525 viscosity refrigerant oil.
IMPORTANT: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring seal to enter the refrigerant system.
4. Carefully slide the new O-ring seal onto the A/C refrigerant line.
5. The O-ring seal must be fully seated.
6. Connect the A/C line.
^ For compression style fittings use a back up wrench on the fitting (2) and tighten the fitting nut (1) to specification.
^ For banjo style fittings install the bolt retaining the banjo type fitting and tighten to specification.
7. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
8. Leak test the fittings of the component using J 39400-A.