Fuel Tank Pressure Sensor: Service and Repair
FUEL TANK PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Remove the fuel tank. Refer to Fuel Tank and EVAP Canister Replacement.
2. Remove the air reference hose (3) from the fuel tank pressure (FTP) sensor.
3. Disconnect the electrical connector (6) from the fuel tank pressure sensor.
4. Remove the fastener (4) retaining the fuel tank pressure sensor and remove the sensor.
INSTALLATION PROCEDURE
1. Clean any contamination from the sensor mounting area.
NOTE: Refer to Component Fastener Tightening Notice in Service Precautions.
2. Install the FTP sensor.
Tighten
Tighten the fastener to 2 N.m (18 lb in).
3. Connect the electrical connector (6) to the fuel tank pressure sensor.
4. Connect the air reference hose (3) to the fuel tank pressure sensor.
5. Install the fuel tank. Refer to Fuel Tank and EVAP Canister Replacement.