Air Temperature Door Replacement - Left
REMOVAL PROCEDURE1. Remove the HVAC Module.
2. Remove the mode actuator.
3. Remove the recirculation actuator.
4. Remove the right temperature actuator. Refer to Air Temperature Actuator Assembly Replacement in HVAC Systems - Automatic.
5. Remove the left temperature actuator. Refer to Air Temperature Actuator Assembly Replacement in HVAC Systems - Automatic.
6. Remove the fasteners that retain the mode actuator bracket.
7. Remove the mode actuator bracket.
8. Remove the upper module case fasteners.
9. Peel back the foam at the heater inlet.
10. Remove the upper case.
11. Remove the left temperature door.
INSTALLATION PROCEDURE
1. Install the left temperature door.
2. Install the upper module case.
3. Install the module case fasteners.
Tighten
Tighten the fasteners to 1.4 N.m (12 lb in).
4. Reapply the foam at the heater inlet.
5. Install the mode actuator and bracket.
6. Install the left temperature actuator. Refer to Air Temperature Actuator Assembly Replacement in HVAC Systems - Automatic.
7. Install the right temperature actuator. Refer to Air Temperature Actuator Assembly Replacement in HVAC Systems - Automatic.
8. Install the recirculation actuator.
9. Install the HVAC module.