Operation CHARM: Car repair manuals for everyone.

Refrigerant Temperature Sensor: Service and Repair

A/C REFRIGERANT LOW TEMPERATURE SENSOR REPLACEMENT

TOOLS REQUIRED
J 39400 Electronic Halogen Leak Detector

REMOVAL PROCEDURE




1. Recover the refrigerant.
2. Disconnect the electrical connector from the sensor.
3. Unscrew the sensor from the refrigerant line.

INSTALLATION PROCEDURE




1. Install the sensor to the refrigerant line.
2. Connect the electrical connector to the sensor.
3. Recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the fittings of the repaired or reinstalled component using J 39400.