Instrument Panel Cluster (IPC) - Replacement
REMOVAL PROCEDURECAUTION: Refer to SIR Caution in Service Precautions.
1. Remove the IP upper trim pad.
2. Remove the instrument cluster trim panel.
3. Remove the 4 fasteners (1) retaining the IP cluster to the IP.
4. Disconnect the electrical connectors (2) on each side of the IP cluster.
5. Remove the IP cluster (3) from the IP.
INSTALLATION PROCEDURE
1. Install the IP cluster (3) to the IP.
2. Connect the electrical connectors (2).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the 4 fasteners (1).
Tighten
Tighten the cluster fasteners to 1.5 N.m (14 lb in).
4. Install the IP cluster trim panel.
5. Install the IP upper trim pad.