Power Door Locks - Inoperative
TEST DESCRIPTIONSteps 1-13:
Steps 14-29:
The number below refer to the step number on the diagnostic table
18. This step identifies the failure as an open or short to ground on the battery positive voltage circuit of the door lock relay, or, a short to ground on one of the door lock actuator control circuits.